Test systems for the hemostasis study
Eilat Laboratorium: Comprehensive Lab Solutions
Home / Test systems for the hemostasis study / Plasma hemostasis
Plasma hemostasis

APTT EK test
The kit is designed for tests: activated partial thromboplastin time (APTT), partial thromboplastin time (PTT) (kephalin time), activated plasma recalcification time (APRT) (kaolin time) in blood plasma both manually and on semi-automatic and automatic coagulometers. They are able to record clot formation in the kaolin presence.
Number of detections: 100-200

APTT test-U 120-240
Reagent kit for to detect the activated partial thromboplastin time (APTT) based on a lyophilically dried mixture of soy phospholipids and ellagic acid.
Number of detections: 120-240

APTT test-U 280-560
Reagent kit for the determining the activated partial thromboplastin time (APTT) based on a lyophilically dried mixture of soy phospholipids and ellagic acid.
Number of detections: 280-560

Diakap-U (40-80)
Reagent kit for detection of the prothrombin time, prothrombin ratio, prothrombin index, prothrombin by Quick and INR in capillary blood.
Number of detections: 40-80

Diakap-U (160-320)
Reagent kit for determination the prothrombin time, prothrombin ratio, prothrombin index, prothrombin by Quick and INR in capillary blood.
Number of detections: 160-320

Diakap-U (360-720)
Reagent kit to detect the prothrombin time, prothrombin ratio, prothrombin index, prothrombin by Quick and INR in capillary blood.
Number of detections: 360-720

OptiFibrinogen-Test-U
Reagent kit for determination of the fibrinogen by Clauss's method. Designed for usage on all types of semi-automatic coagulometers which use reagents containing kaolin.
Number of detections: 160-320

RenaUplastin 2 ml No.3
Thromboplastin (from a rabbit brain) for determination the prothrombin time.
1 Vial - 10-20 determinations

RenaUplastin 2 ml No.4 in the kit with plasma
Thromboplastin (from the rabbit brain) for identification of the prothrombin time.
1 Vial - 10-20 determinations

RenaUplastin 4 ml No.4 in the kit with plasma
Thromboplastin (from a rabbit brain) for determination of the prothrombin time.
1 Vial - 20-40 determinations

RenaUplastin 5 ml No.1
Liquid thromboplastin (from a rabbit brain) for detection of the prothrombin time.

RenaUplastin 8 ml No.10
Thromboplastin (from a rabbit brain) for determination of the prothrombin time. Lyophilically dried ready-to-use mixture of thromboplastin and calcium chloride ISI-certified (1,1-1,2).
1 Vial - 40-80 determinations

RenaUplastin 8 ml No.3
Thromboplastin (from a rabbit brain) for determination of the prothrombin time.
1 Vial - 40-80 determinations

RenaUplastin 8 ml No.3 in the kit with plasma
Thromboplastin (from a rabbit brain) to identify the prothrombin time.
1 Vial - 40-80 determinations

RenaUplastin 10 ml No.1
Liquid thromboplastin (from a rabbit brain) to detect the prothrombin time.

Thrombin-Reagent-U 200-600 determinations
Reagents for determination: prothrombin test
Number of detections: 200-600

Thromboplastin-U (25-50)
Reagent for determination of the prothrombin time. Purified rabbit brain extract (lyophilically dried thromboplastin), water-soluble, ISI-certified, for determination the prothrombin time, prothrombin ratio, prothrombin by Quick, prothrombin index, INR in plasma.
Number of detections: 25-50

Thromboplastin-U (75-150)
Reagent kit for determining the prothrombin time, prothrombin ratio, prothrombin by Quick, prothrombin index, and INR in plasma.
Number of detections: 75-150

Thromboplastin-U (150-300)
Reagent kit for determination of the prothrombin time, prothrombin ratio, prothrombin by Quick, prothrombin index, and INR in plasma.
Number of detections: 150-300

Thromboplastin-U with calcium
For determination of the prothrombin time, prothrombin ratio, prothrombin by Quick and prothrombin index in plasma.
Number of detections: 400-800

Fibrinogen test-U (40-80)
Reagent kit for determination of the fibrinogen by Clauss's method. Designed for usage on all types of semi-automatic and some automatic coagulometers which use reagents without kaolin.
Number of detections: 40-80

Fibrinogen test-U (80-160)
Set of reagents for detection of the fibrinogen by Clauss's method. Designed for usage on all types of semi-automatic and some automatic coagulometers which use reagents without kaolin.
Number of detections: 80-160

Fibrinogen test-U (160-320)
Reagent kit for determination the fibrinogen by Clauss's method. Designed for usage on all types of semi-automatic and some automatic coagulometers, which use reagents without kaolin.
Number of detections: 160-320